Home Page
About Us Latest News Location Contact Us Products Services Links A-Z Index
Capacitors - Power Factor Correction Equipment Automatic Equipment THDI <70% A Series
180Hz Blocking Reactors
Technical Data
Rated Voltage

400 Vac – Max Overvoltage 1.1 Un
Max Overcurrent 1.3 In

Rated Frequency 50 Hz
Rated Power Referred to rated frequency and voltage
Voltage of Auxiliary Circuits 110 Vac feeded by a single-phase transformer
Working Temperature Range -25°C/+50°C
Cubicle 20/10mm sheet steel, protected against corrosion by a phosphating treatment. Epoxy powder painted, RAL 7032 colour (other colours on request)
External Protection Degree: IP30
Locking system:

By screw for cubicle M type
By key for cubicle G type

Ventilation Forced for M & G Types
Isolating Switch Three-pole with door interlocking device
Supply

M type: cable entry from the top
G type: cable entry from the top and the bottom

Wiring By N07VK CEI 20-22 flame retardant cables. Aux. circuits are identified as in the electrical drawing
Contactors

Each bank of capacitors is controlled by a three-pole contactor. To limit the inrush current peaks with reactors.
Rated voltage of auxiliary circuits: 110 Vac, 50 Hz

Fuses Each bank of capacitors is protected by a set of three fuses (NH00 type) with high breaking capacity. Also the auxiliary circuits are protected by fuses.
Capacitors Self-healing metallized polypropylene single-phase capacitors, equipped with overpressure safety device and discharge resistor. Filling: biodegradable non toxic dry type, PCB free. Manufactured using new technologies of metalization Delta connection.
MFA 550 Vac Series, IMQ approved.  
Capacitance tolerance: -5% +10%
Dielectric losses: <0.3W/kvar
Temperature class: -25/D (55°C)
Blocking Reactors Tuning frequency:  180 Hz (3.6 = 7.7%)
Regulator Varmetric measurement by means of a C.T. (secondary 5A)  not supplied
Reference Standards Comply with L.V. 73/23 (93/68) EEC Directive
Capacitors: CEI EN 60831-1/2
Equipment: CEI EN 60439-1
Options (on request ) Digital Voltmeter
Digital Amperometer
Digital P.F. Meter
Protection and Control Instrument SPC  
Protection Degree: IP40 - IP54
 
Range
Dimensions
Type
Power Of Banks
Steps
Isolating
Switch
Regulator
Rated
Current
Weight
Power at 415
Vac 50Hz
M
W x D x H
kVar
No
Amps
Amps
Kg
kVar
420 x 380 x 700
PFM/A
2.5-2.5-5
4
125
PFC5
14.4
41
11
PFM/A
2.5-2.5-5-10
8
125
PFC7
28.8
47
22
420 x 380 x 920
PFM/A
2.5-2.5-5-10-10
12
125
PFC7
43.2
57
33
PFM/A
5-5-10-20
8
125
PFC7
57.6
74
43
420 x 380 x 1140
PFM/A
5-5-10-10-20
10
250
PFC7
72
78
54
PFM/A
10-10-20-20
6
250
PFC7
86.4
100
65
420 x 380 x 1360
PFM/A
10-20-20-20
7
250
PFC7
100.8
112
75
 
PFM/A
10-10-20-20-20
8
250
PFC7
115.2
126
86
L
600 x 625 x 1315
PFL/A
20-40-40
5
250
PFC8
144
220
108
PFL/A
20-40-80
7
400
PFC8
202
260
151
600 x 625 x 1565
PFL/A
20-40-40-80
9
400
PFC8
260
300
194
PFL/A
20-40-80-80
11
630
PFC8
317
325
237
600 x 625 x 1815
PFL/A
20-40-40-80-80
13
630
PFC8
375
365
280
PFL/A
20-40-80-80-80
15
630
PFC8
432
385
323
600 x 625 x 2065
PFL/A
20-40-40-80-80
17
800
PFC8
491
415
365
PFL/A
20-40-80-80-80-80
19
800
PFC8
547
445
409
600 x 625 x 2315
PFL/A
20-40-40-80-80-160
21
1250
PFC8
606
475
452
 
PFL/A
20-40-80-80-80-160
23
1250
PFC8
663
505
495
L
1200 x 625 x 1815
PFL/A
20-40-40-80-160-160
25
2 x 630
PFC8
772
775
538
PFL/A
80-3 x 160
7
2 x 800
PFC8
806
800
603
PFL/A
2 x 80-3 x 160
8
2 x 800
PFC8
922
860
689
1200 x 625 x 2065
PFL/A
80-4 x 100
9
2 x 800
PFC8
1037
920
775
PFL/A
2 x 80-4 x 160
10
2 x 800
PFC8
1152
980
861
1200 x 625 x 2315
PFL/A
80-5 x 160
11
2 x 1250
PFC8
1267
1040
947
PFL/A
1x80 -4x160 -1x240
6
2 x 1250
PFC8
1382
1100
1033
                   
About Us Latest News Location Contact Us Products Services Links A-Z Index